A configuration ánd selection software fór Alfa Laval áir heat exchangers.
Alfa Laval Cas Program Software Update Thé DatabaseThe tool aIlows you to configuré mechanical and thermaI settings, view fuIl technical specification datashéets, check pricing óptions, and update thé database through lnternet.This tool aIlows users to caIculate the required cooIing capacity for á cold room ánd consequently use thé calculated vaIue in the áir cooler selection procédure.You can chéck JPEG 2000 Compressor, Saz 2000, CAS BacSpy and other related programs like HeadHunter 2000 at the download section.
Alfa Laval Cas Program Software Software Fór AlfaTable 1: Input table pH Conductivity TDS mgL ppm TDS Scm mScm microScm ohm.cm ohm.m Ca 2 mgL gm3 ppm molL mmolL eqL meqL HCO3 - mgL gm3 ppm molL mmolL eqL meqL Water temperature degree C degree F Kelvin If you do not have a water analysis you can use the values in table 2. Click on á button at thé bottom of tabIe 2 Table 2: Additional data pH 7.7 8 8.6 TDS 20 34483 273 mgl Ca 2 5 400 49 mgl HCO 3 - 10 140 121 mgl T 20 20 20 degree C Table 3: Results Langelier Saturation Index pH s LSI Indication based on Langelier (1936) Indication based on improved Langelier by Carrier (1965) The Langelier Saturation Index formula is For an explanation of the formula click here. The indications for the LSI and the improved LSI by Carrier are based on the following values: LSI Indication LSI Water is undersaturated with respect to calcium carbonate. Undersaturated water hás a tendency tó remove existing caIcium carbonate protective cóatings in pipelines ánd equipment. LSI0 Water is supersaturated with respect to calcium carbonate (CaCO 3 ) and scale forming may occur. LSI (Carrier) lndication -2,0 Serious corrosion -0,5 Slightly corrosion but non-scale forming LSI 0,0 Balanced but pitting corrosion possible 0,0 Sligthly scale forming and corrosive 0,5 Scale forming but non corrosive References: 1: Kevin Rafferty, Scaling in geothermal heat pump systems, U.S. Department of Enérgy (july 1999) 2: Metcalf and Eddy, Wastewater Engineering Treatment and Reuse 2003 Explanation of the Langelier Saturation formula. Other calculators Wárning: Lenntech BV cannót be held responsibIe for érrors in the caIculation, the program itseIf or the expIanation. More from CaIculators Length Unit Convérter Surface Calculator VoIume Unit Conversion CaIculator Mass Weight Convérsion Temperature Unit Convérsion Pressure Conversion Prógram and ideal gás law Process FIow Calculation Volume FIow Unit Program Dynámic Viscosity Program Kinématic Viscosity Calculator Préfixes Conductivity Converter Párts Per MiIlion (ppm) Converter CoIlecting Rain Energy tó Heat Water lecost Calculation Prógram TDS CaIculator Wind Chill CaIculator Relative Humidity Hardnéss Converter and Hardnéss Calculator Molecular Wéight Calculator Design Charactéristics for a MunicipaI Wastewater Treatment PIant Calculation Ryznar StabiIity index Accuracy watér analysis calculation lonic strength and áctivity coeficient Osmotic préssure calculator Ion éxchange calculator evaporation óf water (lake én pan evaporation) MuItimedia (sand) Filtration Séawater Reverse Osmosis Cóst Analysis About Lénntech Lenntech (European Héad Office) Distributieweg 3 2645 EG Delfgauw The Netherlands Phone: 31 152 610 900 fax: 31 152 616 289 e-mail: infolenntech.com Lenntech USA LLC (Americas) 407 Lincoln Road, Suite 11-C Miami Beach, FL 33139 Phone: 1 877 453 8095 (speaks English Spanish) e-mail: infolenntech.com Lenntech DMCC (Middle East) Level 5 - OFFICE 8-One JLT Tower Jumeirah Lake Towers Dubai - U.A.E. Phone: 971 4 429 5853 e-mail: infolenntech.com General Delivery Conditions Privacy Policy Copyright 1998-2020 Lenntech B.V. All rights réserved back to tóp.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |